Cat A-51 WIFD

Updated Nov 19, 2026• by WO Team 19 min read

notion image
Lens Type
4 Elements Petzval Design
Focal Length
250 mm
Diameter
51 mm
Focal Ratio
f/4.9
Image Circle
48 mm
Focuser
WIFD R&P Focuser
Focuser Travel Length
15 mm
Adapter Included
Tilt Adjuster
Rotator
M54 → M48 Adapter
Optional Flattener
No Flattener Required
Camera Format
Full Frame
APS-C
M4/3
Total Weight
2.2 kg / 4.85 lbs
OTA Weight
1.53 kg / 3.37 lbs
Tube Length
229.4 mm - 266 mm

Diagram Reports

invert
invert

Size Diagram

invert

Parts

invert
  1. Front Bahtinov Mask Cover
  1. Lens Cover with Bahtinov Mask
  1. Dew Shield, retractable – 36mm
    1. Dew Shield Locking Screw
  1. WIFD Focuser [ Tension Adjustment Guide ]
    1. M4 Screw Holes for Finder Bracket
    2. Two Speed 1:10 Ratio Fine Knob
    3. Fine Knob Protecting Cover
    4. Focus ruler scale Window
    5. Focuser Knob with Temperature Gauge ( Can be removed to attach EAF ) [ EAF Installation Guide ]
  1. Sensor Tilt Adjuster [ Adjustment Guide ]
    1. Tilt Adjuster Protecting Cover
  1. Camera Angle Rotator (CAA)
    1. CAA Locking Knob (M6*1.0)
  1. M54 → M48 Adapter
  1. M48 Rear Dust Cap
  1. Handle Bar with Mini Vixen-style Mounting Base (HCRC)
    1. M6 Screw Holes
    2. M4 Screw Holes For Locking Screws
    3. Mounting Base Locking Screws (M4)
  1. Mounting Ring
    1. Mounting Ring Knob
  1. 210mm Dual side Dovetail Plate (Vixen-style & Arca Swiss Type) (PRC210-A51)

Operation Guide

Focuser Tension Adjustment

William Optics focusers are typically smooth and ready to use without any adjustment. For larger telescopes, tightening the Quick Tension Adjustment Knob can help prevent tube slippage. Other than this, we recommend not touching any screws on the focuser. If adjustment is necessary, please consult a qualified technician.
 
There’s two side to build WIFD focuser tension:

BOTTOM / Rack & Pinion Gear

invert
  • Quick tension adjustment knob
  • Smoothness adjustment - Pull in (3mm Hex)
  • Smoothness adjustment - Push out (2mm Hex)
  • Please Don’t Touch
  • Top cover screw Can be removed to attach the electronic devices such as EAF (refer to Installing EAF) or be used as a spare.
    • Telescope models from June 2025 no longer include the top cover screw.
       

TOP / Focuser Draw Tube

invert
  • Guider/Finder bracket mounting screws (2.5mm Hex)
  • Focuser Draw Tube Tension Screws Please Don’t Touch
  • Focuser Hardware Stop Screw (varies from models) Please Don't Touch
 
Notice
  • When operating the telescope with a motorized focuser, do not overtighten the focuser tension. Excessive tension may damage the focuser mechanism.
  • Make small and slow adjustments. Do not turn anything too much at once.

Sensor Tilt Adjustment

  1. Locate the pair of diagonally opposing screws corresponding to the affected corners.
notion image
notion image
1. Remove the rotator knob.
notion image
notion image
2. Remove the ring cover.
notion image
notion image
3. The tilt adapter is inside.
  1. Use the 2mm hex key to loosen the pull-in screw of the screw group closest to side where stars appear too close, and loosen the push-out screws of the group on the opposite side (too far).
invert
  1. Adjust the push-out screws in the "too close" group and the pull-in screw in the "too far" group until the tilt is corrected.
  1. Gently snug all screws to hold the final position.
Note
  • Make small adjustments at a time—1/8 turn is recommended for fine control.
  • Adjust other screws if necessary to maintain overall balance.
  • If the tilt becomes worse or is severely misaligned, perform a reset:
    • 1. Loosen all push-out screws
      2. Tighten all pull-in screws fully
      3. Back out each pull-in screw by the same number of turns
      4. Begin tilt adjustment again from this neutral position

Back Spacing Range on Petzval Systems

Petzval telescopes do not rely on a single, exact back focus distance. Instead, they are designed to reach focus within a supported back spacing range, providing flexibility when using different cameras and accessories.
As long as the complete camera setup falls within this range, the focuser can reach focus normally. If the setup goes beyond it, focus may no longer be achievable.
invert
For astrophotography, a back spacing of 55 ± 3 mm is recommended to limit drawtube extension and reduce the risk of light leakage.
For more details on back spacing, see the support article Back Spacing Range on Petzval Systems

Installing Erect Prism

notion image
  1. Position the telescope with the rear end facing upward.
notion image
  1. Remove the CAA locking knob.
notion image
  1. Remove the protective cover.
notion image
  1. Unscrew the 4 pull-in screws from the Tilt Adjuster.
invert
⚠︎ Keep the 4 Pull-in Screws in a safe place.
notion image
  1. Remove the Rear Adapter.
notion image
  1. Install the Erecting Prism and tighten it securely.
notion image
  1. Loosen the EP rotation locking knob and rotate to the desired position. Retighten the knob to secure it.
notion image
  1. Insert the eyepiece to begin visual observation.
Reassembly Caution
When reinstalling the Tilt Adjuster, gradually and evenly tighten the four pull-in screws in a crisscross pattern, using multiple passes. Do not fully tighten one screw at a time, as this may cause uneven pressure and misalignment.

Installing EAF

notion image
  1. Turn the telescope over and remove the Tension screw.
notion image
  1. Remove the top cover screw near the temperature gauge with 2mm Allen key.
Starting from June 2025, new telescope models no longer include the top cover screw. (Skip Step 2)
notion image
  1. Release (don’t remove) two inner knob screws.
notion image
  1. Remove the temperature gauge knob.
notion image
  1. Find the flat side on the shaft and turn it to face the hole.
notion image
  1. Put the 5-6mm Flexible coupling on the shaft and lock the two inner screws.
notion image
  1. Put the EAF body on and lock the two inner screws.
On Step 6 & 7:
Please make sure one of the screws is lock on the flat side (D-cut profile)
invert
notion image
  1. Align the screw holes.
notion image
  1. Lock the four M4 bracket screws.
notion image
 
⚠︎ The Cat A-51 has a short focus travel of 15 mm. When using an EAF for the first time, start with small step increments and verify the movement direction. Set the appropriate travel limits before normal operation to prevent mechanical damage.

Care & Safety Instructions

Solar Safety Warning

Never point your telescope or finder scope at the Sun without a proper solar filter securely mounted to the front of the telescope.
Even a brief, unfiltered glimpse of the Sun can permanently damage your eyes or your camera’s image sensor.
  • Use only front-mounted solar filters made by trusted manufacturers. These filters must cover the front of the telescope’s dew shield securely.
  • Do not use solar eyepiece filters. They are unsafe and can fail under sunlight.
invert
With the correct solar filter in place, you can safely observe and photograph the Sun without damaging your eyes, your camera, or your telescope.

Telescope Care & Storage

To preserve the optical quality and lifespan of your William Optics telescope, please follow these essential care and storage practices:
  • Allow time to acclimate After use, let the telescope adjust to room temperature before storage. During this period, keep the optical tube open and uncovered to allow moisture to evaporate naturally.
  • Ensure dryness Make sure the entire telescope is completely dry, especially the optics and interior tube, and free of dew or moisture before putting it away.
  • Use proper storage conditions Store your telescope in a dry, dust-free environment with a stable temperature. Avoid high heat or humidity. Dehumidifiers or silica gel are recommended for long-term protection.
  • Prevent dust accumulation Always place dust caps on both ends when not in use, or cover the telescope with a clean plastic sheet if it’s not stored in a case.
Following these steps will help maintain optimal performance and prevent damage to sensitive components such as lenses, mirrors, and coatings.
For a detailed cleaning and maintenance guide, please refer to the full article: Cleaning and Maintenance of Telescopes

Clearance Around WIFD Focuser

To avoid interference between the focuser knobs and the mount, make sure the telescope is properly aligned on the mounting rings.
Loosen the rings slightly and adjust the telescope position so that both focuser knobs are level and parallel to the mount. This ensures sufficient clearance from the saddle plate and prevents accidental contact or obstruction during use.
invert

Accessories Map

For Astrophotography

For Visual Observation

Compatible Eyepieces
  • UWAN 82° | 4mm, 7mm, 16mm (under 20mm)